Search results for "Thermal response"

showing 10 items of 13 documents

The importance of thermal history: costs and benefits of heat exposure in a tropical, rocky shore oyster.

2015

Although thermal performance is widely recognized to be pivotal in determining species' distributions, assessment of this performance is often based on laboratory acclimated individuals, neglecting their proximate thermal history. The thermal history of a species sums the evolutionary history and, importantly, the thermal events recently experienced by individuals, including short-term acclimation to environmental variations. Thermal history is perhaps of greatest importance for species inhabiting thermally challenging environments and therefore assumed to be living close to their thermal limits, such as in the tropics. To test the importance of thermal history the responses of the tropical…

0106 biological sciencesSettore BIO/07 - EcologiaOysterHot TemperaturePhysiologyAcclimatizationMicroclimateTrade-offAquatic Science010603 evolutionary biology01 natural sciencesAcclimatizationRocky shoreOxygen ConsumptionEnergy absorption efficiencybiology.animalAquatic scienceAnimalsEcosystemEcological relevanceMolecular BiologyEcology Evolution Behavior and SystematicsEcosystembiologyEcologyAnimal010604 marine biology & hydrobiologyMedicine (all)TropicsThermal responseMicroclimatebiology.organism_classificationEcology Evolution Behavior and SystematicOstreidaeOstreidaeInsect ScienceAnimal Science and ZoologyHeat-Shock ResponseThe Journal of experimental biology
researchProduct

Allee effect in a manipulative parasite within poikilothermic host under temperature change

2022

AbstractTemperature and intraspecific competition are important factors influencing the growth of all organisms, including parasites. The temperature increase is suggested to stimulate the development of parasites within poikilothermic hosts. However, at high parasite densities, this effect could be diminished, due to stronger intraspecific competition. Our study, for the first time, addressed the joint effects of warming and parasite abundances on parasite growth in poikilothermic hosts. The growth of the common fish parasite larvae (trematode Diplostomum pseudospathaceum) within the rainbow trout at different infection intensities and temperatures (15°C and 18°C) was experimentally invest…

0106 biological sciencesthermal responsecrowding effectZoologyDiplostomum pseudospathaceumTrematode InfectionsBiology010603 evolutionary biology01 natural sciencesHost-Parasite InteractionsFish Diseases03 medical and health sciencessymbols.namesakeeye flukekirjolohiloisetmetacercariaeAnimalsParasite hostingParasitessize variationEcosystem030304 developmental biologyAllee effect0303 health sciencesHost (biology)imumadotTemperatureparasite growthpopulaatiodynamiikkaInfectious DiseasesPoikilotherminfection intensitiesOncorhynchus mykisssymbolslämpötilaAnimal Science and ZoologyParasitologyTrematodaympäristönmuutoksetParasitology
researchProduct

Thermal response test analysis for U-pipe vertical borehole heat exchangers under groundwater flow conditions

2021

[EN] Conventional models used in the analysis of thermal response test data only consider conduction as heat transfer mechanism. In cases where presence of groundwater is detected, convection heat transmission plays an important role, so its influence must be determined in the calculation of the effective thermal conductivity, usually overestimated in these situations, increasing its value the higher the power injected and the time elapsed. In this work, based on the data collected in a borehole located at UPV (Valencia) in which have been carried out three thermal response tests with different characteristics, has been implemented a variation of the finite line source model introducing an …

060102 archaeologyGroundwater flowRenewable Energy Sustainability and the Environment020209 energyBoreholeThermal response test (TRT) analysis06 humanities and the arts02 engineering and technologyMechanicsThermal conductionLine sourceGround water advectionUndisturbed ground temperature recoveryThermal conductivityThermal response testHeat transferHeat exchangerMAQUINAS Y MOTORES TERMICOS0202 electrical engineering electronic engineering information engineeringEnvironmental scienceEffective thermal conductivity0601 history and archaeologyBorehole thermal resistanceGeothermal heat exchanger
researchProduct

Experimental analysis of a thermoactive underground railway station

2022

Little is known about the real energy potential of thermoactive underground infrastructures, such as railway stations, that can act as a heating/cooling provider for the built environment. This study presents the results of thermomechanical full-scale in situ testing and numerical analysis of a thermoactive underground train station. The thermal performance and related geostructural impact of a portion of the new underground energy infrastructure (UEI) installed at the Lancy-Bachet train station in Geneva (Switzerland) are analyzed. Heating and cooling tests simulating real operative geothermal conditions are considered. Particular attention is given to ((i) the monitored wall-tunnel hydrot…

Energy geostructuresThermomechanical behaviorSoil–structure interactionUnderground infrastructuresGeotechnical Engineering and Engineering GeologyThermal response testSoil structure interactionEnergy wallsGeotechnical engineeringComputers in Earth SciencesUnderground railway stationSafety Risk Reliability and QualityThermal response testGeologyGeomechanics for Energy and the Environment
researchProduct

Application of a new wireless instrument to characterize thermal properties of ground coupled heat exchangers

2010

Abstract In this work, we report the design and laboratory test of a new instrument to measure the temperature of the heat transfer fluid along the borehole exchanger (BHE) by autonomous wireless sensor. The instrument consists of a device, which inserts and extracts miniaturized wireless sensors in the borehole with a mechanical subsystem, composed by a circulating pump and two valves. This device transmits to the sensors the acquisition configuration, and downloads the temperature data measured by the sensor along its way through the borehole heat exchanger. Each sensor is included in a sphere of 25 mm diameter and contains a transceiver, a microcontroller, a temperature sensor and a powe…

Engineeringbusiness.industryElectrical engineeringBoreholeMechanical engineeringGeneral MedicineTemperature measurementMicrocontrollerData acquisitionThermal response testHeat exchangerThermalbusinessCirculating pump
researchProduct

Extraction of thermal characteristics of surrounding geological layers of a geothermal heat exchanger by 3D numerical simulations

2016

Ground thermal conductivity and borehole thermal resistance are key parameters for the design of closed Ground-Source Heat Pump (GSHP) systems. The standard method to determine these parameters is the Thermal Response Test (TRT). This test analyses the ground thermal response to a constant heat power injection or extraction by measuring inlet and outlet temperatures of the fluid at the top of the borehole heat exchanger. These data are commonly evaluated by models considering the ground being homogeneous and isotropic. This approach estimates an effective ground thermal conductivity representing an average of the thermal conductivity of the different layers crossed by perforation. In order …

Ground coupled heat pumpEngineering020209 energyPerforation (oil well)BoreholeEnergy Engineering and Power Technology02 engineering and technologyNumerical simulationIndustrial and Manufacturing EngineeringThermal Response Testlaw.inventionThermal conductivity020401 chemical engineeringlawHeat exchangerHeat transfer0202 electrical engineering electronic engineering information engineeringGeotechnical engineering0204 chemical engineeringbusiness.industryTechnic-Economical optimizationMechanicsThermal transmittanceEnergy efficiencyThermal response testHeat transferMAQUINAS Y MOTORES TERMICOSbusinessMATEMATICA APLICADAHeat pump
researchProduct

Novel Wireless Sensor System for Dynamic Characterization of Borehole Heat Exchangers

2011

The design and field test of a novel sensor system based in autonomous wireless sensors to measure the temperature of the heat transfer fluid along a borehole heat exchanger (BHE) is presented. The system, by means of two specials valves, inserts and extracts miniaturized wireless sensors inside the pipes of the borehole, which are carried by the thermal fluid. Each sensor is embedded in a small sphere of just 25 mm diameter and 8 gr weight, containing a transceiver, a microcontroller, a temperature sensor and a power supply. A wireless data processing unit transmits to the sensors the acquisition configuration before the measurements, and also downloads the temperature data measured by the…

Heat pumpsEngineeringGeography & travelBoreholeMechanical engineeringlcsh:Chemical technologyBiochemistryGeothermal energyArticleAnalytical ChemistryWireless sensorsHeat exchangerThermalWirelesslcsh:TP1-1185Thermal analysisElectrical and Electronic EngineeringThermal analysisInstrumentationddc:910business.industryheat pumps; geothermal energy; thermal analysis; wireless sensorsAtomic and Molecular Physics and OpticsMicrocontrollerThermal response testMAQUINAS Y MOTORES TERMICOSTransceiverbusiness
researchProduct

Aquatic cycling-What do we know? A scoping review on head-out aquatic cycling

2017

Over the past few years, aquatic cycling has become a trending fitness activity. However, the literature has not been reviewed exhaustively. Therefore, using scoping review methodology, the aim of this review was to explore the current state of the literature concerning aquatic cycling. This study specifically focused on study designs, populations and outcomes. A comprehensive search of seven databases (PubMed, MEDLINE, Cinahl, Embase, PEDro, Web of Science, WorldCat) was conducted up to 30th September 2016. GoogleScholar, World Cat, ResearchGate, specific aquatic therapy websites and aquatic therapy journals were searched to identify additional literature. Full-text publications in English…

MalePhysiologyMaternal HealthPsychological interventionlcsh:MedicineBlood PressureVascular MedicineDatabase and Informatics Methods0302 clinical medicinePregnancyHeart RateMedicine and Health SciencesMedicinePublic and Occupational HealthDatabase Searchinglcsh:ScienceMusculoskeletal SystemMultidisciplinaryTemperatureObstetrics and GynecologyResearch AssessmentSports ScienceExercise TherapyBody Fluids3. Good healthBloodSystematic reviewMeta-analysisLegsFemaleAnatomyAEROBIC EXERCISECyclingWATER IMMERSIONPREGNANT-WOMENSportsResearch ArticleSystematic ReviewsLEG EXERCISEPOWERCardiologyMEDLINECINAHLResearch and Analysis Methods03 medical and health sciencesCOLD-WATEREnvironmental healthHumansAquatic therapyCENTRAL BLOOD-VOLUMESports and Exercise MedicinePlasma VolumeTHERMAL RESPONSESExercisebusiness.industryClinical study designLimbs (Anatomy)lcsh:RWaterBiology and Life SciencesPhysical Activity030229 sport sciencesRATE-VARIABILITYPHYSIOLOGICAL-RESPONSESPhysical FitnessWomen's Healthlcsh:Qbusiness030217 neurology & neurosurgeryPLOS ONE
researchProduct

The effects of skin and core tissue cooling on oxygenation of the vastus lateralis muscle during walking and running

2016

Skin and core tissue cooling modulates skeletal muscle oxygenation at rest. Whether tissue cooling also influences the skeletal muscle deoxygenation response during exercise is unclear. We evaluated the effects of skin and core tissue cooling on skeletal muscle blood volume and deoxygenation during sustained walking and running. Eleven male participants walked or ran six times on a treadmill for 60 min in ambient temperatures of 22°C (Neutral), 0°C for skin cooling (Cold 1), and at 0°C following a core and skin cooling protocol (Cold 2). Difference between oxy/deoxygenated haemoglobin ([diffHb]: deoxygenation index) and total haemoglobin content ([tHb]: total blood volume) in the vastus lat…

MalespectroscopyVastus lateralis musclePhysical Therapy Sports Therapy and RehabilitationBlood volumeWalking030204 cardiovascular system & hematologythermal responsesQuadriceps MuscleRunningHemoglobinsYoung Adult03 medical and health sciencesOxygen Consumption0302 clinical medicinemedicineHumansOrthopedics and Sports MedicineTreadmillta315heat economy (metabolism)DeoxygenationCore (anatomy)Blood VolumeSpectroscopy Near-InfraredChemistrySkeletal muscle030229 sport sciencesGas exchangeOxygenationAnatomyhemoglobinCold Temperaturemedicine.anatomical_structureAnesthesiaexercise (people)Energy MetabolismSkin Temperatureear-infrared spectroscopyBody Temperature RegulationJournal of Sports Sciences
researchProduct

Cold exposure enhances fat utilization but not non-esterified fatty acids, glycerol or catecholamines availability during submaximal walking and runn…

2013

Cold exposure modulates the use of carbohydrates and fat during exercise. This phenomenon has mostly been observed in controlled cycling studies, but not during walking and running when core temperature and oxygen consumption are controlled, as both may alter energy metabolism. This study aimed at examining energy substrate availability and utilization during walking and running in the cold when core temperature and oxygen consumption are maintained. Ten lightly clothed male subjects walked or ran for 60-min, at 50% and 70% of maximal oxygen consumption, respectively, in a climatic chamber set at 0°C or 22°C. Thermal, cardiovascular, and oxidative responses were measured every 15-…

Physiologykylmäaltistuscold exposurerasvahapotchemistry.chemical_elementBlood lipidsOxidative phosphorylationglycerol030204 cardiovascular system & hematologyBiologyOxygenthermal responseslcsh:Physiologyrasva-aineenvaihdunta03 medical and health scienceschemistry.chemical_compound0302 clinical medicineAnimal sciencePhysiology (medical)fatHeart rateGlycerolglyseroliOriginal Research Articleta315Exerciselcsh:QP1-981kuormauskuormitusfat metabolismVO2 max030229 sport sciencesRespiratory quotientGlucosechemistryBiochemistrykatakolamiinitEnergy sourceEnergy Metabolismkatekoliamiinit
researchProduct